中文

← Timeline · November 2026

Infrastructure

Preferred Networks extends the r2SCAN mode of its Matlantis PFP force field to 96 elements, rare earths and actinides included, and reports it runs three to four times faster than SevenNet-Omni

Evidence 3/5: Checked against existing evidencearXiv 2611.23873 ↗

What happened

A technical note from Preferred Networks and Matlantis Corporation describes PFP v9, which adds r2SCAN training data for the lanthanides from praseodymium to lutetium, the elements from polonium to curium, and clusters and adsorbed molecules. Crystals with the new elements matched experimental formation enthalpies with a mean error of 93 meV/atom, against 81 for elements covered before. On one A100 GPU it handled five to ten times as many atoms as SevenNet-Omni, a public r2SCAN-trained model, and computed forces three to four times faster.

Why it matters

r2SCAN is a DFT method that agrees better with experiment than the common PBE, and a force field trained on it gives that accuracy at force-field cost. Version 8 used r2SCAN for only part of the periodic table; version 9 covers the same 96 elements as its PBE mode, so rare-earth and actinide compounds and adsorption on surfaces can now be run in the more accurate mode.

Evidence and limits

The company's own note on its own model, with no outside test. Adsorption energies are about as accurate as DFT-PBE overall, but chemisorbed molecules were overbound by 361 meV on average, against 176 for PBE, and there is no Hubbard U correction yet for strongly correlated oxides. The speed test covers three simple systems.

About this entry

Authors Daiki Shintani, Chikashi Shinagawa

Happened November 18, 2026Added November 21, 2026Edited by Dekun Sun

Evidence

The result is evaluated against measurements, records or operational systems that already exist, under a defined evaluation procedure. What is checked is a particular result, such as a prediction, a design or a forecast, not a ranking of models on a benchmark, which is rung 2. A model's own predictions scored against real measurements or records it was not trained on (held-out experiments, clinical labels, observed weather) are rung 3, even when the release is a database of predictions; the database alone is rung 2. A single worked example that reproduces an already-known result is not a defined procedure.

Who evaluated it Internal: Evaluated by the originating team.

How the evidence ladder works →

Source

arXiv 2611.23873 arxiv.org ↗

How far it was read Full PDF of v1 (18 Nov 2026, 11 pages) the editor supplied, read in full. The digest's MLIP Arena ranking and hydrogen-combustion figure are not in this note and were left out

Argued around this time

All commentary →

Read next

Its place on the timeline →