Imaging liver cells picks up compound activity at lower doses than standard toxicity assays, but does not predict cell-free assays

Evidence 3/5: Checked against existing evidenceCell Systems ↗Axiom Bio · Broad Institute

What happened

Axiom Bio, the Broad Institute's Imaging Platform and co-authors at the EPA and Bayer ran the Cell Painting imaging assay and two cytotoxicity assays on primary human liver cells against 1,085 compounds at eight concentrations. Among the 131 compounds active in every readout, the images flagged activity at 2.5 times lower concentrations than the metabolic assay, 7.9 than counting nuclei and 15.8 than the membrane-damage one. Predicting 412 curated ToxCast endpoints, they worked on cytotoxicity and cell-based assays and no better than shuffled labels on cell-free ones.

Why it matters

Axiom Bio sells liver-toxicity prediction from exactly this kind of imaging, and this is the public paper behind it: the images carry what happens inside a cell and nothing about a protein in a tube, so what the method can replace is bounded by biology, not by model size. A pretrained vision transformer and a convolutional network scored about the same as hand-engineered image features, so the limit here is the assay, not the architecture. The cells are one pooled five-donor hepatocyte lot, so donor variation is untested, and the ToxCast comparison uses other labs' assay designs.

About this entry

Authors Jessica D. Ewald, Katherine L. Titterton, Anne E. Carpenter, Shantanu Singh

Happened March 27, 2026Source published May 1, 2026Added October 6, 2026Edited by Dekun Sun

Evidence

The result is evaluated against measurements, records or operational systems that already exist, under a defined evaluation procedure. What is checked is a particular result, such as a prediction, a design or a forecast, not a ranking of models on a benchmark, which is rung 2. A model's own predictions scored against real measurements or records it was not trained on (held-out experiments, clinical labels, observed weather) are rung 3, even when the release is a database of predictions; the database alone is rung 2. A single worked example that reproduces an already-known result is not a defined procedure.

Who evaluated it Internal: Evaluated by the originating team.

How the evidence ladder works →

Source

Cell Systems doi.org ↗

How far it was read Cell Systems 17(5), 2026; the preprint's full text (bioRxiv 2025.01.22.634152) read for the printed numbers, the journal record via Europe PMC

Organisations

  • Axiom Bio

    Screens compounds on live human liver cells at scale and trains AI models on the images to predict drug toxicity before human trials.