Research
Ångström AI and Astex predict drug solubility from a machine-learned potential, with errors of 1.53 log units on 10 compounds
Evidence 3/5: Checked against existing evidencearXiv 2611.33408 ↗University of Cambridge


Research
Evidence 3/5: Checked against existing evidencearXiv 2611.33408 ↗University of Cambridge
J. Harry Moore, Laurence Midgley, Gábor Csányi and colleagues at Ångström AI and the University of Cambridge, with chemists from Astex Pharmaceuticals, built λ-MACE, a machine-learned potential tuned for free-energy calculations, and used it to compute how well drug-like molecules dissolve. On 70 medicinal-chemistry compounds from the FreeSolv set its hydration free energies were off by 0.59 kcal/mol (RMSE), against 0.75 for the OPLS4 force field. Combined with crystal sublimation energies for 10 compounds, solubility came out 1.53 log units off.
Solubility decides how much of an oral drug can be absorbed and whether early compounds can be tested at all, and predictors fitted to measured data degrade on molecules unlike their training set. A drug company paid for and co-wrote this test of computing it from physics instead, and the paper says where the error sits: each half of the calculation must get below 0.5 kcal/mol, and the crystal half is the harder. That tells teams building or buying free-energy tools what to fix first.
Scored against published measurements, on 70 small neutral molecules and 10 crystals whose experimental structures were given; the model covers no charged molecules. 1.53 log units is worse than experimental error (0.17 to 0.6) and than 1 kcal/mol (0.73). An earlier mix of methods reached 1.45 on 25 molecules that include these 10. Predicting the crystal structure itself, which real use needs, was not tested.
The preprint was posted to arXiv on 24 November 2026. Its eight authors are J. Harry Moore, Javier Antorán, Laurence Midgley, Nicholas J. Browning and Gábor Csányi of Ångström AI, a San Francisco company (all but Browning also at the University of Cambridge's Engineering Laboratory), and Paul Mortenson, Davide Branduardi and Pavel Buslaev of Astex Pharmaceuticals in Cambridge. The acknowledgments say Astex funded the work. Midgley is the corresponding author.
Free energy perturbation is already common in drug R&D, but its accuracy is limited by the empirical force field it runs on. The team instead ran the whole system, drug and water, on a machine-learned potential trained on quantum calculations. They started from an earlier alchemical MACE model by Moore and colleagues, which had reached about 0.5 kcal/mol on 36 molecules, and added training data where it was weak: the SPICE 2 set, and 73,000 configurations of 2,240 Enamine fragments in water that they computed themselves, because sulfur compounds and phenols were under-represented.
On 70 neutral FreeSolv compounds chosen for medicinal-chemistry relevance, λ-MACE's hydration free energies had an RMSE of 0.59 kcal/mol, against 0.75 for OPLS4; the authors say its outliers are compounds whose experimental values are themselves uncertain. On a set of larger compounds where the GAFF force field errs most, its RMSE was 1.37 against GAFF's 4.64. For crystals it computed sublimation free energies from experimental structures and did better than dispersion-corrected DFT (PBE-G NC). Hydration took about 100 GPU hours per compound on eight A100s, sublimation about one GPU hour.
Combining the two for 10 compounds gave an intrinsic-solubility RMSE of 1.53 log units. Experimental accuracy is 0.17 to 0.6 log units and 1 kcal/mol equals 0.73. Swapping in measured sublimation energies improved it significantly, and the paper names the crystal leg as the larger source of error. The previous physics-based best was 0.72 log units on three molecules; Palmer and colleagues reported 1.45 on 25. The authors conclude that each leg must reach about 0.5 kcal/mol, and that real use needs predicted crystal structures in place of measured ones. They note that MACE-POLAR-1 overestimates water density by 8%, which rules it out for hydration for now.
Happened November 24, 2026Added November 27, 2026Edited by Dekun Sun
The result is evaluated against measurements, records or operational systems that already exist, under a defined evaluation procedure. What is checked is a particular result, such as a prediction, a design or a forecast, not a ranking of models on a benchmark, which is rung 2. A model's own predictions scored against real measurements or records it was not trained on (held-out experiments, clinical labels, observed weather) are rung 3, even when the release is a database of predictions; the database alone is rung 2. A single worked example that reproduces an already-known result is not a defined procedure.
Who evaluated it Internal: Evaluated by the originating team.
How far it was read Full text read in the arXiv PDF (version 1): introduction, results, conclusion and methods; the compound tables in the appendix skimmed
Collegiate research university in Cambridge, England.